Note: If the air bell is removed, use a new gasket when installing. During installation, the threads of the air flow meter mounting bolts must be coated with a blocking compound.
Removing
1. Remove the air filter assembly as described in Chapter 4.
2. Remove the bolt securing the air flow meter to the air filter cover (see illustration).
3. Unscrew the four mounting bolts on the inside of the air filter cover, remove the two stiffeners, remove the air flow meter (see illustration).
4. If required, the air bell can be removed from the inside of the air filter cover.
Installation
5. Install in reverse order, paying attention to the following.
6. If the air bell has been removed, use a new gasket when installing it.
7. Coat the threads of the four airflow meter mounting bolts that are installed inside the air cleaner cover with thread blocking compound.