2. Disconnect the electrical wiring from the valve (see resist. illustration) EVAP, disconnect the fuel line quick connectors using the tool and plug the fuel lines with suitable plugs.
11.2 Valve (2) EVAP (on the example of models equipped with the Z18XE engine) - the arrow indicates the mounting bolt: 1. Wiring connector; 2. Fuel lines; 3. Device Hazet-4501-1
3. Turn out a fixing bolt (see illustration 11.2) and release the valve from the holder.
4. Installation is carried out in the reverse order.