Removing
1. Disconnect the negative cable from the battery.
2. Remove the distributor breaker cover as described in Chapter 17.
3. Disconnect the distributor wiring.
4. Turn off two bolts of fastening, remove the distributor from a head of the block of cylinders.
5. Check the condition of the O-ring on the back of the distributor, replace if necessary.
Installation
6. Install in reverse order.
But note that the distributor must be installed so that the wiring connector is located on the left side of the distributor housing from above, when viewed from the cover of the breaker-distributor.