2. To remove the replaceable element, you must first disconnect the connector (see accompanying illustration) the electrical wiring of the mass air flow sensor by pressing the connector clamps.
18.2 Sensor (3) for measuring mass air flow: 1. Electrical wiring connector; 2. Retainer
3. Loosen the mounting clamps (see illustration) and remove the air intake duct.
18.3 Air cleaner - the cover mounting screws are indicated by arrows: 4. Fastening clamps; 5. Air intake duct; 6. Air cleaner cover; A. Lid holders
Text copied from this portal OPELBOOK
Remove the 5 fastening screws, then lift the edge of the air cleaner cover on the engine side, release the opposite edge of the cover from the holders and remove it. 4 Remove the filter element, wipe the inner surfaces of the cover and the air cleaner body with a dry cloth and install a new replaceable element. Assembly is carried out in the reverse order.
Attention! At the factory, the air cleaner cover is secured with self-tapping screws, they can be used no more than 10 times. If the cover is no longer held tightly on the air cleaner body, it is necessary to drill holes of a suitable diameter in the attachment points and use ordinary bolts and nuts to secure the cover.