Radiator
Radiator with finned aluminum tubes and side tanks. A safety valve is built into the radiator cap.
Colour marking and digital index of the radiator cap: blue, 90.096.561.
Opening pressure of safety valve, kg/cm²: 1.25-1.30.
Water pump
The centrifugal water pump shaft rotates in a sealed double-row ball bearing.
Pump pulley outer diameter, mm: 100.
Angle of the pulley groove walls, deg.: 40.
Gear ratio of crankshaft pulley to pump pulley: 1.1:1.
Thermostat
A thermostat with a solid temperature-sensitive filler is installed in the box.
Valve opening start temperature,°C: 91.
Full valve opening temperature,°C: 107.
Generator drive belt
Belt size, mm: 9.5x950.
Brand and type of belt: Ventiflex 1111.
Belt tension, kgf:
- new: 45.0;
- worked: 25-30.
Fan
The fan has a plastic five-blade impeller mounted on the shaft of an electric motor, which is switched on and off by the electric fan switch.
Fan motor switch-on temperature,°C: 97.
Fan motor switch-off temperature,°C: 93.
Impeller diameter, mm: 280.
Coolant
Engine cooling and cabin heating system capacity, l: 5.7
The liquid used: a mixture of distilled water and antifreeze in a ratio of 80% and 20% at temperatures up to -10°C, 48% and 52% at temperatures up to -40°C.
Replacement frequency: every two years of operation.