7.1. Clamp (2) for fastening the torsional vibration damper (1)
2. Remove the inner CV joint boot from the right drive shaft (see Section 6).
3. Cut the damper mounting clamp and remove the damper from the shaft in the direction indicated by the arrow (see illustration 7.1).
4. Installation is performed in the reverse order of removal. To determine the installation location of the torsional vibration damper, measure the distance from its outer (mounting) edge to the corresponding groove on the drive shaft - a = 225±5 mm (see illustration 7.1).