Removal of air after filling the tract of the power system occurs automatically, which explains the absence of bleed valves.
1. Start the engine (the procedure may take a little longer than usual, especially if the fuel from the system was completely drained - crank the crankshaft with the starter for no longer than 10 seconds, if necessary, try again after waiting at least 30 seconds) and let it run for a couple of minutes at fast idle. After the air plugs are completely removed from the power system path, the stability of the idle speed should be restored.
2. Insufficient stability of the engine operation indicates that not all the air has left the path - for a couple of minutes, raise the engine speed, then reset it to idle again. Continue pumping until the desired idle stability is achieved.