Removing
1. Disconnect the wire terminal from the battery «masses» (-) and remove the storage box.
2. Disconnect and remove air duct 1 (see illustration).
3. Disconnect the holder 2 of the wiring harness (see illustration 13.2).
4. Disconnect the multi-pin plug 3 of the resistor board by depressing the retaining clip (see illustration).
5. Disconnect the low pressure hose 5 from the diaphragm valve of the air distribution damper and release it from the holder 4 (see illustration 13.4).
6. Unscrew the bolts securing the motor cover and remove it together with the motor (see arrows in illustration 13.4).
7. Unscrew the bolts securing the cover 8 to the electric motor 6 and remove the cover by pressing the sleeve 7 inward (see illustration).
Installation of the electric motor of the fan is carried out in sequence, return to removal.