Solenoid valve and pump motor relay
1. The solenoid valve and pump motor relay are installed on the hydraulic modulator. Disconnect the negative battery cable first.
2. Remove the bolt on the power steering reservoir.
3. Remove the screw and take out facing from the hydraulic modulator.
4. Pull out the appropriate relay. The small relay is for the solenoid valve, the large relay is for the return pump motor.
5. Install the new relay using the reverse procedure to removal.
Swing limiter relay
6. The swing limiter relay is located on the left side of the engine compartment, behind the left front suspension mount.
7. Remove facing of the relay and pull out the relay.
8. Install a new relay and trim and reconnect the negative battery cable.