Common parameters
System type - Closed, pressurized, with front-mounted radiator, separate expansion tank and electric fan. Water pump driven by gas distributor (petrol models and diesel engines 1.7 l) or auxiliary (diesel models 2.0 l) belt.
Coolant volume
see chapter Current service.
Thermostat
Characteristic |
Meaning |
Type (All models)
|
wax-filled |
Opening start temperature,°C | |
Petrol models | |
|
80 |
|
92 |
Diesel models | |
|
89 |
|
92 |
Full opening | |
Petrol models (All models)
|
107 |
Diesel models | |
|
92 |
|
107 |
Electric fan
Response temperature,°С |
|
|
100 |
Shutdown temperature,°С |
|
|
95 |
Air conditioner
Characteristic |
Meaning |
Refrigerant type |
R134a |
Coolant volume, gr |
700 |
Type of refrigerant oil |
SP10 |
Refrigerator oil volume, cm 3 |
|
Petrol models |
|
|
135 |
|
150 |
Diesel models |
|
|
150 |
Tightening force of threaded connections, Nm
Connection type |
Meaning |
Fastening the refrigerant tube to the receiver-drier
and capacitor
|
20 |
Fastening of a drainage tube of the condenser of the A/V system to
semi
|
5 |
Fastening the cooling fan frame to the radiator
|
5 |
Mounting the pressure sensor to the dryer receiver
|
9 |
Fastening of a crossbar of a steering to a bulkhead
|
25 |
Air Conditioning Compressor Support Mount
| |
Petrol models | |
|
25 |
|
20 |
Diesel models | |
|
20 |
Fastening ATF cooling lines to the radiator (only models
with AT)
|
30 |
coolant temperature sensor | |
Petrol models | |
|
20 |
|
14 |
|
20 |
|
10 |
Diesel models | |
|
20 |
|
23 |
|
10 |
Thermostat housing fixing | |
Petrol models | |
|
20 |
Diesel models | |
|
24 |
|
8 |
Thermostat cover fixing (only petrol models)
| |
|
10 |
|
8 |
|
20 |
|
15 |
Water pump | |
Petrol models | |
|
8 |
|
25 |
Diesel models | |
|
24 |
|
25 |
|
20 |
Water pump pulley (only diesel models) | |
|
10 |
|
20 |
Visitor comments