Disconnect the radiator inlet hose from the water pump and the outlet hose from the thermostat housing. Unscrew with a square head wrench «at 9» drain plug on the cylinder block behind the generator and drain the coolant.
Close the drain plug.
Disconnect the coolant outlet hose to the heater from the cylinder head.
Fill the system with coolant through the expansion tank until coolant emerges from the hole for the coolant outlet hose to the heater.
Connect the heater inlet hose.
Add fluid to the expansion tank to a level 1 cm above the mark «KALT» («Cold»).