Disconnect the wire from the negative battery terminal.
Fill the reservoir with brake fluid and close it with an airtight stopper.
Remove the hydroblock cover.
Unscrew and disconnect the hydraulic system pipelines from the hydraulic unit. noticing the markings of their position.
Disconnect electrical connector.
Remove the relay from the hydraulic unit.
Loosen the bolts securing the hydraulic unit bracket.
Disconnect the jumper from the hydraulic unit on «mass».
The valve body is installed in the reverse order of removal.