Execution sequence
1. Remove the starter (see «Starter - removal and installation»).
2. Using a 13 mm socket wrench, unscrew the fastening nut and remove the wire from the contact bolt of the solenoid relay.
3. Using the TORX T25 key, we unscrew the three bolts securing the retractor relay.
4. Remove the retractor.
5. We remove the return spring from the relay housing...
...and remove the o-ring from it. A damaged ring must be replaced.
6. Remove the armature of the retractor relay, disengaging it from the drive lever.
7. Install the parts in reverse order. When installing, make sure that the tip of the solenoid relay engages with the drive lever.